80~140º C Heat Pump Dryer for Industrial

Product Details
Customization: Available
Fuel: Electric Heating
Installation: Packaged Boiler
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (29)
  • 80~140º C Heat Pump Dryer for Industrial
  • 80~140º C Heat Pump Dryer for Industrial
  • 80~140º C Heat Pump Dryer for Industrial
  • 80~140º C Heat Pump Dryer for Industrial
  • 80~140º C Heat Pump Dryer for Industrial
  • 80~140º C Heat Pump Dryer for Industrial
Find Similar Products

Basic Info.

Model NO.
LYDS-120XW
Structure
Water Tube
Media
Steam and Water
Water Circulation
Natural Circulation
Drum Placement
Vertical Boiler
Pressure
Pressure
Manufacturing Level
A
Usage
Industrial, Power Station
Compressor
Screw
Control
Carel
Circuit
Inverter
Refrigerant
High Temperature Refrigerant
Transport Package
Timber
Specification
100kw
Trademark
LYD
Origin
China
HS Code
8402190000

Product Description

We are professional to offer high temperature heat pump.

Our heat pump can offer 70~150ºC, useing low GWP and ODP green refrigerant.

Show us your requirements, then we will find a best solution for your application.

Our solution based on R1234ze, CO2, R1233zde,R515B.

R1234ze and R515B can produce max 90ºC hot air, R744 can produce 120ºC hot air and R1233zde can produce 145ºC hot air
80~140º C Heat Pump Dryer for Industrial

 
Model LYDS-50XW LYDS-150XW LYDS-200XW LYDS-250XW LYDS-300XW
water source 20ºC/15ºC;heating side 75/80ºC heating capacity kW 55 165 220 275 330
Input kW 23.8 71.4 95.2 119 142.8
COP w/w 2.33 2.33 2.33 2.33 2.33
Cooling capacity kW 31.2 93.6 124.8 156 187.2
heating flow m³/h 9.46 28.37 37.83 47.29 56.75
Cooling flow m³/h 5.37 16.10 21.46 26.83 32.19
compressor type   Scroll Scroll Scroll Scroll Scroll
control   fixed fixed fixed fixed fixed
Condenser Type   PHE/Tube
Max water pressure MPa 2.0/1.0
Connection   DN50 DN100 DN125 DN125 DN150
water P drop kPa 50 62 65 70 85
Evaporator type   PHE
Max water pressure MPa 2.0/1.0
connection   DN50 DN80 DN100 DN100 DN125
water P drop kPa 45 59 63 70 85
Control   Carel PLC
Heating way   circulation circulation circulation circulation circulation
Power supply   380V/50Hz/50Hz
Weight Kg 500 1500 2000 2500 3000
Size mm 900×800×1906 2600×1500×1950 2600×1500×1950 3500x1500x1950 3500x1500x1950
Pressure (MPa) H pressure:3.0    Low Pressure:0.8
Refrigerant   R1234ze R1234ze R1234ze R1234ze R1234ze
water source range ºC 0~55
Output range ºC 40-90
Max output ºC 95
Noise dB(A) ≤55 ≤60 ≤65 ≤75 ≤80
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now